Brand: Schneider Electric
Reference: GV2ME14
Magnetothermic circuit breaker 6.10 A TeSys GV2 screw connection. AC network type. Utilization category AC-3 according to IEC 60947-4-1 Category A according to IEC 60947-2. Rated operating frequency 50/60 Hz in accordance with IEC 60947-4-1. Breaking capacity 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] power rated short-circuit service breaking current 100% at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100% at 440 V AC 50/60 Hz conforming to IEC 60947-2 100% at 500 V AC 50 /60 Hz conforming to IEC 60947-2 75% at 690 V AC 50/60 Hz conforming to IEC 60947-2 100% at 400/415 V AC 50/60 Hz conforming to IEC 60947-2. Trip unit rating 6.10 A. Thermal-magnetic trip unit technology. Magnetic trip intensity 138 A. Benefits: Total protection concentrated in a single product. TeSys GV2 motor circuit breakers are only 45mm wide and are divided according to their level of features and functions: control type, breaking capacity, motor protection and accessories. Applications: Industry, infrastructure, buildings, etc. Control and protection of motors, in accordance with IEC 947-2 and IEC 947-4-1 standards, Easy to insert into any configuration thanks to fixing by screw or hook on mounting profiles.
Circuit breaker 6.10 A screw connection TeSys GV2. AC network type. Utilization category AC-3 according to IEC 60947-4-1 Category A according to IEC 60947-2. Rated operating frequency 50/60 Hz in accordance with IEC 60947-4-1. Breaking capacity 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] power rated short-circuit service breaking current 100% at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100% at 440 V AC 50/60 Hz conforming to IEC 60947-2 100% at 500 V AC 50 /60 Hz conforming to IEC 60947-2 75% at 690 V AC 50/60 Hz conforming to IEC 60947-2 100% at 400/415 V AC 50/60 Hz conforming to IEC 60947-2. Trip unit rating 6.10 A. Thermal-magnetic trip unit technology. Magnetic trip intensity 138 A. Benefits: Total protection concentrated in a single product. TeSys GV2 motor circuit breakers are only 45mm wide and are divided according to their level of features and functions: control type, breaking capacity, motor protection and accessories. Applications: Industry, infrastructure, buildings, etc. Control and protection of motors, in accordance with IEC 947-2 and IEC 947-4-1 standards, Easy to insert into any configuration thanks to fixing by screw or hook on mounting profiles.