Brand: ABB
Reference: 1SBL157001R1310
AF12-30-10 CONT.3P BOB 100-250V AC-DC
3-pole, 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 5.5 kW/400 V AC (AC-3) or 7-1. /2 hp / 480 V UL and switched power circuits up to 28 A (AC-1) or 28 A UL general purpose.
Thanks to AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large variations in control voltage, reducing the energy consumption of the panel and ensuring distinct operations on unstable networks. Additionally, surge protection is built-in, offering a compact solution.
AF contactors have a block-type design and can be easily expanded with additional auxiliary contact blocks and a wide additional range of accessories.
Classification
Minimum order quantity:
1 piece
Tariff code:
85364900
Popular Downloads
Instructions and manuals:
1SBC101027M6801
CAD dimensional drawing:
2CDC001079B0201
Dimensions
Product width:
45mm
Product length:
77mm
Height of the product:
86mm
Product weight:
0.27 kg
Technical
Number of main contacts NO:
3
Number of main NC contacts:
0
Number of auxiliary contacts NO:
1
Number of NC auxiliary contacts:
0
Rules:
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Nominal operating voltage:
Auxiliary Circuit 690 V
Main Circuit 690 V
Nominal frequency (f):
Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional free air thermal current (Ith):
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Nominal operating current AC-1 (Ie):
(690 V) 40 °C 28 A
(690 V) 60 °C 28 A
(690 V) 70 °C 24 A
Nominal operating current AC-3 (Ie):
(415 V) 60 °C 12 A
(440 V) 60 °C 12 A
(500 V) 60 °C 12.5 A
(690 V) 60 °C 9 A
(380 / 400 V) 60 °C 12 A
(220 / 230 / 240 V) 60 °C 12 A
Nominal operating current AC-3e (Ie):
(415 V) 60 °C 12 A
(440 V) 60 °C 12 A
(500 V) 60 °C 12.5 A
(690 V) 60 °C 9 A
(380 / 400 V) 60 °C 12 A
(220 / 230 / 240 V) 60 °C 12 A
AC-3 rated operating power (Pe):
(400 V) 5.5 kW
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
Nominal operating power AC-3e (Pe):
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
Nominal operating current AC-15 (Ie):
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated short duration current Low voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
for 0.1 s 140 A
for 1 s 100 A
Maximum breaking capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum electrical switching frequency:
(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Nominal DC-1 operating current (Ie):
(110 V) 1-Pole, 40 °C 15 A
(110 V) 1-Pole, 60 °C 15 A
(110 V) 1-Pole, 70 °C 15 A
(110 V) 2 Poles in Series, 40 °C 27 A
(110 V) 2 Poles in Series, 60 °C 27 A
(110 V) 2 Poles in Series, 70 °C 24 A
(110 V) 3 Poles in Series, 40 °C 27 A
(110 V) 3 Poles in Series, 60 °C 27 A
(110 V) 3 Poles in Series, 70 °C 24 A
(220 V) 2 Poles in Series, 40 °C 15 A
Show more
Nominal DC-3 operating current (Ie):
(110 V) 1-Pole, 40 °C 7 A
(110 V) 1-Pole, 60 °C 7 A
(110 V) 1-Pole, 70 °C 7 A
(110 V) 2 Poles in Series, 40 °C 27 A
(110 V) 2 Poles in Series, 60 °C 27 A
(110 V) 2 Poles in Series, 70 °C 24 A
(110 V) 3 Poles in Series, 40 °C 27 A
(110 V) 3 Poles in Series, 60 °C 27 A
(110 V) 3 Poles in Series, 70 °C 24 A
(220 V) 2 Poles in Series, 40 °C 7 A
Show more
Nominal operating current DC-5 (Ie):
(110 V) 1-Pole, 40 °C 4 A
(110 V) 1-Pole, 60 °C 4 A
(110 V) 1-Pole, 70 °C 4 A
(110 V) 2 Poles in Series, 40 °C 15 A
(110 V) 2 Poles in Series, 60 °C 15 A
(110 V) 2 Poles in Series, 70 °C 15 A
(110 V) 3 Poles in Series, 40 °C 27 A
(110 V) 3 Poles in Series, 60 °C 27 A
(110 V) 3 Poles in Series, 70 °C 24 A
(220 V) 2 Poles in Series, 40 °C 4 A
Show more
Nominal operating current DC-13 (Ie):
(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Nominal insulation voltage (Ui):
acc. to IEC 60947-4-1 690 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600V
Nominal voltage supported by impulses (Uimp):
6 kV
Maximum mechanical switching frequency:
3600 cycles per hour
Nominal voltage of the control circuit (Uc):
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Operating time:
Between Coil De-energization and NC Contact Closing 13 ... 98 ms
Between Coil De-energization and NO Contact Opening 11 ... 95 ms
Between Coil Energization and NC Contact Opening 38 ... 90 ms
Between Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on contactors:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Assembly using screws (not supplied):
2 x M4 screws placed diagonally
Main circuit connection capacity:
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 4 mm²
Rigid Stranded 1/2x 1 ... 6 mm²
Auxiliary circuit connection capacity:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Connection of the capacity control circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid Solid 1/2x 1 ... 2.5 mm²
Rigid Stranded 1/2x 1 ... 2.5 mm²
Cable stripping length:
Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 10 mm
Degree of protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal type:
Screw Terminals
Technical UL/CSA
NEMA size:
0
NEMA rated continuous current:
18 A
NEMA rated power:
(115 V AC) Single Phase 1 Hp
(200 V AC) Three Phase 3 Hp
(230 V AC) Single Phase 2 Hp
(230 V AC) Three Phase 3 Hp
(460 V AC) Three Phase 5 Hp
(575 V AC) Three Phase 5 Hp
UL/CSA maximum operating voltage:
Main Circuit 600 V
UL/CSA General Purpose Classification:
(600 V AC) 28 A
UL/CSA rated power:
(120 V AC) Single Phase 1 hp
(200 ... 208 V AC) Three Phase 3 hp
(220 ... 240 V AC) Three Phase 3 hp
(240 V AC) Single Phase 2 hp
(440 ... 480 V AC) Three Phase 7-1/2 hp
(550 ... 600 V AC) Three Phase 10 hp
UL/CSA main circuit connection capacity:
Rigid Solid 1/2x 16-10 AWG
Rigid Stranded 1/2x 16-10 AWG
Connection capacity UL/CSA auxiliary circuit:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
UL/CSA connection capacity control circuit:
Rigid Solid 1/2x 18-14 AWG
Rigid Stranded 1/2x 18-14 AWG
UL/CSA tightening torque:
Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 13 in·lb
Environment
Ambient temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climate resistance:
Category B according to IEC 60947-1 Annex Q
Maximum allowable operating altitude:
Without Derating 3000 m
Shock resistance according to IEC 60068-2-27:
Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: At 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
Vibration resistance according to IEC 60068-2-6:
4g Closed Position & 2g Open position 5...300 Hz
Material Compliance
Conflict Minerals Reporting Template (CMRT):
9AKK108467A5658
REACH declaration:
2CMT2021-006202
RoHS information:
2CMT2021-006277
RoHS status:
Following EU Directive 2011/65/EU
Toxic Substances Control Act - TSCA:
2CMT2023-006525
WEEE B2C / B2B:
Business To Business
WEEE category:
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations (Document Number)
ABS certificate:
ABS_20-2060694-PDA
BV Certificate:
BV_2634H24898C0
CB Certificate:
CB_SE-108879
CCC Certificate:
CCC_2010010304445624
CQC certificate:
CQC2010010304445624
CQC2020010304298240
Declaration of conformity - CCC:
2020980304001253
2020980304001082
Declaration of conformity - CE:
1SBD250000U1000
Declaration of conformity - UKCA:
1SBD250031U1000
DNV Certificate:
DNV_TAE00001AF-4
EAC Certificate:
EAC_RU_FRME77B03447
GOST certificate:
GOST_POCCFR.ME77.B07175.pdf
KC certificate:
KC_HW02016-15005C
LR Certificate:
LRS_LR23403517TA-02
RINA Certificate:
RINA_ELE240318XG
RMRS Certificate:
RMRS_1802705280
UL certificate:
UL-US-2150887-5
UL-CA-2142658-5
UL Listing Card:
E312527
Packaging Information
Packaging Level 1 Units:
box 1 piece
Packaging Level 1 Width:
87mm
Level 1 Long Packaging:
79mm
Packaging Level 1 High:
47mm
Packaging Level 1 Weight:
0.27 kg
Packaging Level 1 EAN:
3471523110335
Packaging Level 2 Units:
box 27 piece
Packaging Level 2 Width:
250mm
Level 2 Long Packaging:
300mm
High Level 2 Packaging:
315mm
Level 2 Packaging Weight:
7.29 kg
Level 3 Units Package:
1296 pieces
Classifications
Object classification code:
Q
ETIM 4:
EC000066 - Magnet contactor, AC-switching
ETIM 5:
EC000066 - Magnet contactor, AC-switching
ETIM 6:
EC000066 - Power contactor, AC switching
ETIM 7:
EC000066 - Power contactor, AC switching
ETIM 8:
EC000066 - Power contactor, AC switching
Electronic class:
V11.0: 27371003
UNSPSC:
39121529
IDEA Granular Category Code (IGCC):
4758 >> Iec Contactors
E number (Finland):
3706222
E number (Sweden):
3211364