Brand: Schneider Electric
Reference: A9F75240
iC60N Acti 9, 2P, 40A, D curve, 50/60 Hz, IP20, Thermal-magnetic circuit breaker, Suitable for isolating, Contact position indicator, Control type: Toggle, Local signaling: Trip indicator, Mode Mounting Type: Fixed, Mounting Bracket: DIN Rail, Earth Leakage Protection: Independent Block, 85x36x78.5mm, 0.25kg, White. Breaking capacity: 10 kA Icu conforming to IEC 60947-2, 380...415 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 72...125 V DC, 36 kA Icu from conforming to EN 60947-2, 12...133 V AC 50/60 Hz, 20 kA Icu conforming to EN 60947-2, 220...240 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947 -2, 72...125 V DC, 10 kA Icu conforming to EN 60947-2, 380...415 V AC 50/60 Hz, 36 kA Icu conforming to IEC 60947-2, 12...133 V AC 50/60 Hz, 20 kA Icu conforming to IEC 60947-2, 220...240 V AC 50/60 Hz, 6000 A Icn conforming to EN 60898-1, 400 V AC 50/60 Hz, 6 kA Icu conforming to EN 60947-2, 440 V AC 50/60 Hz, 6 kA Icu conforming to IEC 60947-2, 440 V AC 50/60 Hz, 6000 A Icn conforming to IEC 60898-1, 400 V AC 50/60 Hz, utilization category: category A according to IEC 60947-2, category A according to EN 60947-2, suitable for isolation: yes according to IEC 60898-1, yes according to EN 60898- 1, yes according to EN 60947-2, yes according to IEC 60947-2, standards: EN 60898-1, IEC 60947-2, IEC 60898-1, EN 60947-2.
Circuit breaker iC60N Acti 9, 2P, 40A, curve D, 50/60 Hz, IP20, Thermal-magnetic, Suitable for sectioning, Contact position indicator, Type of control: Handle, Local signaling: Indicator trip, Mounting mode: Fixed, Mounting support: DIN rail, Earth leakage protection: Independent block, 85x36x78.5mm, 0.25kg, White. Breaking capacity: 10 kA Icu conforming to IEC 60947-2, 380...415 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 72...125 V DC, 36 kA Icu from conforming to EN 60947-2, 12...133 V AC 50/60 Hz, 20 kA Icu conforming to EN 60947-2, 220...240 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947 -2, 72...125 V DC, 10 kA Icu conforming to EN 60947-2, 380...415 V AC 50/60 Hz, 36 kA Icu conforming to IEC 60947-2, 12...133 V AC 50/60 Hz, 20 kA Icu conforming to IEC 60947-2, 220...240 V AC 50/60 Hz, 6000 A Icn conforming to EN 60898-1, 400 V AC 50/60 Hz, 6 kA Icu conforming to EN 60947-2, 440 V AC 50/60 Hz, 6 kA Icu conforming to IEC 60947-2, 440 V AC 50/60 Hz, 6000 A Icn conforming to IEC 60898-1, 400 V AC 50/60 Hz, utilization category: category A according to IEC 60947-2, category A according to EN 60947-2, suitable for isolation: yes according to IEC 60898-1, yes according to EN 60898- 1, yes according to EN 60947-2, yes according to IEC 60947-2, standards: EN 60898-1, IEC 60947-2, IEC 60898-1, EN 60947-2.