Brand: Schneider Electric
Reference: A9F79250
Circuit breaker iC60N Acti 9, 2P, 50A, curve C, IP20, Thermal-magnetic, Suitable for isolating, Contact position indicator, Control type: Handle, Local signaling: Trip indicator, Mounting mode: Fixed, Mounting support: DIN rail, Earth leakage protection: Freestanding block, 85x36x78.5mm, 0.25kg, White. Breaking capacity: 10 kA Icu conforming to EN 60947-2, 380...415 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 380...415 V AC 50/60 Hz, 20 kA Icu conforming to IEC 60947-2, 220...240 V AC 50/60 Hz, 6000 A Icn conforming to EN 60898-1, 400 V AC 50/60 Hz, 6000 A Icn conforming to IEC 60898 -1, 400 V AC 50/60 Hz, 36 kA Icu conforming to EN 60947-2, 12...133 V AC 50/60 Hz, 6 kA Icu conforming to EN 60947-2, 440 V AC 50/ 60 Hz, 10 kA Icu conforming to EN 60947-2, 72...125 V DC, 20 kA Icu conforming to EN 60947-2, 220...240 V AC 50/60 Hz, 6 kA Icu conforming with IEC 60947-2, 440 V AC 50/60 Hz, 36 kA Icu conforming to IEC 60947-2, 12...133 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 72. ..125 V DC, utilization category: category A conforming to IEC 60947-2, category A conforming to EN 60947-2, suitable for isolating: yes conforming to IEC 60947-2, yes conforming to EN 60947- 2, yes according to IEC 60898-1, yes according to EN 60898-1, standards: IEC 60947-2, EN 60898-1, IEC 60898-1, EN 60947-2.
Curve C iC60N Acti 9, 2P, 50A, circuit breaker, IP20, Thermal-magnetic, Suitable for isolating, Contact position indicator, Control type: Handle, Local signaling: Trip indicator, Mounting method : Fixed, Mounting support: DIN rail, Earth leakage protection: Independent block, 85x36x78.5mm, 0.25kg, White. Breaking capacity: 10 kA Icu conforming to EN 60947-2, 380...415 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 380...415 V AC 50/60 Hz, 20 kA Icu conforming to IEC 60947-2, 220...240 V AC 50/60 Hz, 6000 A Icn conforming to EN 60898-1, 400 V AC 50/60 Hz, 6000 A Icn conforming to IEC 60898 -1, 400 V AC 50/60 Hz, 36 kA Icu conforming to EN 60947-2, 12...133 V AC 50/60 Hz, 6 kA Icu conforming to EN 60947-2, 440 V AC 50/ 60 Hz, 10 kA Icu conforming to EN 60947-2, 72...125 V DC, 20 kA Icu conforming to EN 60947-2, 220...240 V AC 50/60 Hz, 6 kA Icu conforming with IEC 60947-2, 440 V AC 50/60 Hz, 36 kA Icu conforming to IEC 60947-2, 12...133 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 72. ..125 V DC, utilization category: category A conforming to IEC 60947-2, category A conforming to EN 60947-2, suitable for isolating: yes conforming to IEC 60947-2, yes conforming to EN 60947- 2, yes according to IEC 60898-1, yes according to EN 60898-1, standards: IEC 60947-2, EN 60898-1, IEC 60898-1, EN 60947-2.