Automatic Circuit Breaker Ic60N 4P 20A Curve-D

Brand: Schneider Electric

Reference: A9F75420

Offer: €179.63
PVP: €598.78
€179.63

Description

iC60N Acti 9, 4P, 20A, D curve, 50/60 Hz, IP20, Thermal-magnetic circuit breaker, Suitable for isolating, Contact position indicator, Control type: Toggle, Local signaling: Trip indicator, Mode Mounting Type: Fixed, Mounting Bracket: DIN Rail, Earth Leakage Protection: Free Standing Block, 85x72x78.5mm, 0.5kg, White. Breaking capacity: 36 kA Icu conforming to EN 60947-2, 12...133 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947-2, 180...250 V DC, 10 kA Icu from conforming to IEC 60947-2, 180...250 V DC, 6 kA Icu conforming to EN 60947-2, 440 V AC 50/60 Hz, 36 kA Icu conforming to IEC 60947-2, 12...133 V AC 50/60 Hz, 20 kA Icu conforming to IEC 60947-2, 220...240 V AC 50/60 Hz, 6000 A Icn conforming to EN 60898-1, 400 V AC 50/60 Hz, 20 kA Icu conforming to EN 60947-2, 220...240 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947-2, 380...415 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 380...415 V AC 50/60 Hz, 6000 A Icn conforming to IEC 60898-1, 400 V AC 50/60 Hz, 6 kA Icu conforming to IEC 60947-2, 440 V AC 50/60 Hz, utilization category: category A according to IEC 60947-2, category A according to EN 60947-2, suitable for isolation: yes according to EN 60947-2, yes according to IEC 60947- 2, yes according to EN 60898-1, yes according to IEC 60898-1, standards: EN 60947-2, IEC 60947-2, IEC 60898-1, EN 60898-1.

Details

More information

Circuit breaker iC60N Acti 9, 4P, 20A, curve D, 50/60 Hz, IP20, Thermal-magnetic, Suitable for isolating, Contact position indicator, Type of control: Handle, Local signaling: Indicator trip, Mounting mode: Fixed, Mounting support: DIN rail, Earth leakage protection: Independent block, 85x72x78.5mm, 0.5kg, White. Breaking capacity: 36 kA Icu conforming to EN 60947-2, 12...133 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947-2, 180...250 V DC, 10 kA Icu from conforming to IEC 60947-2, 180...250 V DC, 6 kA Icu conforming to EN 60947-2, 440 V AC 50/60 Hz, 36 kA Icu conforming to IEC 60947-2, 12...133 V AC 50/60 Hz, 20 kA Icu conforming to IEC 60947-2, 220...240 V AC 50/60 Hz, 6000 A Icn conforming to EN 60898-1, 400 V AC 50/60 Hz, 20 kA Icu conforming to EN 60947-2, 220...240 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947-2, 380...415 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 380...415 V AC 50/60 Hz, 6000 A Icn conforming to IEC 60898-1, 400 V AC 50/60 Hz, 6 kA Icu conforming to IEC 60947-2, 440 V AC 50/60 Hz, utilization category: category A according to IEC 60947-2, category A according to EN 60947-2, suitable for isolation: yes according to EN 60947-2, yes according to IEC 60947- 2, yes according to EN 60898-1, yes according to IEC 60898-1, standards: EN 60947-2, IEC 60947-2, IEC 60898-1, EN 60898-1.

Comments

There are no opinions yet Be the first to review!

Questions

No questions yet Do you have any doubt?

Best price

Have you seen it cheaper?
×

Receive our news

See details + -
By checking this option we will send you the best offers and exclusive promotions and discounts to your email address. You can unsubscribe at any time.
Set your cookies preferences
We use cookies and similar technologies to offer you a personalized, safe, reliable experience and to be able to measure page performance to continue improving our services. For more information or to edit your cookie preferences at any time, check the Cookies policy page
Go out