Brand: Schneider Electric
Reference: A9F79450
iC60N Acti 9 Circuit Breaker, 4P, 50A, C curve, IP20, thermal-magnetic, suitable for isolating, contact position indicator, handle control, trip indicator, fixed mounting, DIN rail mounting, a leakage protection ground with independent block,, 85x72x78.5mm, 0.5kg, White. Breaking capacity: 36 kA Icu conforming to EN 60947-2, 12.133 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 380.415 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947 -2, 380.415 V AC 50/60 Hz, 6000 A Icn conforming to IEC 60898-1, 400 V AC 50/60 Hz, 20 kA Icu conforming to EN 60947-2, 220.240 V AC 50/60 Hz, 6 kA Icu conforming to IEC 60947-2, 440 V AC 50/60 Hz, 6 kA Icu conforming to EN 60947-2, 440 V AC 50/60 Hz, 36 kA Icu conforming to IEC 60947-2, 12.133 V AC 50/60 Hz, 6000 A Icn conforming to EN 60898-1, 400 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947-2, 180.250 V DC, 10 kA Icu conforming to IEC 60947-2 , 180.250 V DC, 20 kA Icu conforming to IEC 60947-2, 220.240 V AC 50/60 Hz, utilization category: category A conforming to IEC 60947-2, category A conforming to EN 60947-2, suitable for isolation: yes according to EN 60898-1, yes according to EN 60947-2, yes according to IEC 60898-1, yes according to IEC 60947-2, standards: EN 60947-2, EN 60898-1, IEC 60947-2, IEC 60898-1.
Curve C iC60N Acti 9, 4P, 50A, circuit breaker, IP20, thermal-magnetic, suitable for isolating, contact position indicator, handle control, trip indicator, fixed mounting, DIN rail support, protection against earth leakage with independent block, 85x72x78.5mm, 0.5kg, White. Breaking capacity: 36 kA Icu conforming to EN 60947-2, 12.133 V AC 50/60 Hz, 10 kA Icu conforming to IEC 60947-2, 380.415 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947 -2, 380.415 V AC 50/60 Hz, 6000 A Icn conforming to IEC 60898-1, 400 V AC 50/60 Hz, 20 kA Icu conforming to EN 60947-2, 220.240 V AC 50/60 Hz, 6 kA Icu conforming to IEC 60947-2, 440 V AC 50/60 Hz, 6 kA Icu conforming to EN 60947-2, 440 V AC 50/60 Hz, 36 kA Icu conforming to IEC 60947-2, 12.133 V AC 50/60 Hz, 6000 A Icn conforming to EN 60898-1, 400 V AC 50/60 Hz, 10 kA Icu conforming to EN 60947-2, 180.250 V DC, 10 kA Icu conforming to IEC 60947-2 , 180.250 V DC, 20 kA Icu conforming to IEC 60947-2, 220.240 V AC 50/60 Hz, utilization category: category A conforming to IEC 60947-2, category A conforming to EN 60947-2, suitable for isolation: yes according to EN 60898-1, yes according to EN 60947-2, yes according to IEC 60898-1, yes according to IEC 60947-2, standards: EN 60947-2, EN 60898-1, IEC 60947-2, IEC 60898-1.