2P Differential Switch Pfim-40/2/003-A Ca, Eaton series Moeller xPole - PFIM Type AC, A, U, R RCCB. Differential circuit breaker (RCCB), 40A, 2p, 30mA, type A, MW.

Details

More information

2P Differential Switch Pfim-40/2/003-A Ca, Eaton series Moeller xPole - PFIM Type AC, A, U, R RCCB. Differential automatic switch (RCCB), 40A, 2p, 30mA, type A, MW.

GENERAL SPECIFICATIONS

PRODUCT NAME

Eaton Moeller series xPole - PFIM Type AC, A, U, R RCCB

PRODUCT LENGTH/DEPTH

80 mm

HEIGHT OF THE PRODUCT

76mm

PRODUCT WIDTH

35mm

WEIGHT OF THE PRODUCT

0.193 kg

CONFORMITY(S)

RoHS compliant

CERTIFICATION(S)

IEC/EN 61008

MODEL CODE

PFIM-40/2/003-A-MW

DELIVERY SCHEDULE

APPLICATION

Differential automatic switch for residential and commercial applications

XPole - Switchgear for residential and commercial applications

NUMBER OF POLES

Two poles

TRIG TIME

No delay

NOMINAL AMPERAGE

40 A

NOMINAL SHORT CIRCUIT RESISTANCE

10 kA

RATED FAULT CURRENT

30 mA

TYPE OF SENSITIVITY

Sensitive to impulse current

IMPULSE SUPPORTED CURRENT

Partially protected against surges 250 A

TYPE

PFIM

Differential automatic switch:

Type A

TECHNICAL DATA - ELECTRICAL

NOMINAL VOLTAGE

230 V AC

NOMINAL OPERATING VOLTAGE (EU) - MAX.

230 V

ASSIGNED INSULATION VOLTAGE (UI)

440 V

ASSIGNED VOLTAGE SUPPORTED TO THE IMPULSE (UIMP)

4 kV

RATED FAULT CURRENT - MIN.

0.03 A

RATED FAULT CURRENT - MAX.

0.03 A

FREQUENCY CLASSIFICATION

50 Hz

SHORT CIRCUIT CLASSIFICATION

63 A (max. permissible replacement fuse)

TYPE OF LEAKAGE CURRENT

A

NOMINAL INTERRUPTION AND RESIDUAL CLOSURE CAPACITY

500 A

RESERVE FUSE OVERLOAD ALLOWED - MAX.

25 A gG/gL

RATED SHORT-DURATION WITHSTANDING CURRENT (ICW)

10 kA

TRANSIENT OVERVOLTAGE CURRENT CAPACITY

0.25 kA

TEST CIRCUIT RANGE

196 V AC - 264 V AC

DEGREE OF POLLUTION

2

USEFUL LIFE, ELECTRICAL

4000 operations

TECHNICAL DATA - MECHANICAL

FRAME

45mm

WIDTH IN SERIES OF MODULAR SPACING

2

INTEGRATED WIDTH (NUMBER OF UNITS)

35 mm (2 SU)

INTEGRATED DEPTH

70.5mm

ASSEMBLY METHOD

DIN rail

Quick fixing with 2 latch positions for DIN rail IEC/EN 60715

DEGREE OF PROTECTION

IP20

IP20, IP40 with suitable housing

TERMINALS (UPPER AND LOWER)

Open mouth/elevator terminals

TERMINAL CAPACITY (RIGID CABLE)

1.5 mm² - 35 mm²

CONNECTABLE CONDUCTOR SECTION (RIGID CORE) - MIN.

1.5 mm²

CONNECTABLE CONDUCTOR SECTION (RIGID CORE) - MAX.

35 mm²

TERMINAL CAPACITY (BRAIDED CABLE)

16 mm² (2x)

CONNECTABLE CONDUCTOR SECTION (MULTIFIRE) - MIN.

1.5 mm²

CONNECTABLE CONDUCTOR SECTION (MULTI-WIRE) - MAX.

16 mm²

TERMINAL PROTECTION

Safe for fingers and hands, DGUV VS3, EN 50274

THICKNESS OF THE MUDDER MATERIAL

0.8 mm - 2 mm

USEFUL LIFE, MECHANICAL

20,000 operations

PERMITTED STORAGE AND TRANSPORTATION TEMPERATURE - MIN.

-35 °C

PERMITTED STORAGE AND TRANSPORTATION TEMPERATURE - MAX.

60 °C

CLIMATE RESISTANCE

25-55°C / 90-95% relative humidity according to IEC 60068-2

Comments

There are no opinions yet Be the first to review!

Questions

No questions yet Do you have any doubt?

Best price

Have you seen it cheaper?
×

Receive our news

See details + -
By checking this option we will send you the best offers and exclusive promotions and discounts to your email address. You can unsubscribe at any time.
Set your cookies preferences
We use cookies and similar technologies to offer you a personalized, safe, reliable experience and to be able to measure page performance to continue improving our services. For more information or to edit your cookie preferences at any time, check the Cookies policy page
Go out