Brand: Eaton
Reference: 235439
4P Differential Switch Pfim-40/4/003-A-Mw, Residual current circuit breaker for residential and commercial applications.
Product name
Eaton Moeller xPole series - PFIM type AC, A, U, R RCCB
Part number.
PFIM-40/4/003-A-MW
Product length/depth
80 millimeters
Height of the product
76 millimeters
Product width
70 millimeters
Product Weight
0.349 kilograms
Compliance
RoHS Compliant
Certifications
CEI/EN 61008
Commercial name of the product
xPole - PFIM type CA, A, U, R
type of product
RCCB
Product subtype
None
Delivery program
Request
Three-phase application without N is not allowed (400V AC phase-phase)
Residual current circuit breaker for residential and commercial applications.
xPole - Switchgear for residential and commercial applications
Number of poles
four poles
shooting time
Not delayed
Amperage rating
40 A
Nominal short circuit resistance
10 kA
Fault current classification
30mA
Type of sensitivity
Sensitive to pulse current
Impulse supported current
Partially resistant to surges 250 A
Type
PFIM
Residual current circuit breakers
Write a
Technical Data - Electrical
Voltage
230 V AC / 400 V AC
Nominal operating voltage (Ue) - max.
400 volts
Nominal insulation voltage (Ui)
440 volts
Nominal impulse withstand voltage (Uimp)
4 kilovolts
Nominal fault current - min.
0.03 A
Nominal fault current - max.
0.03 A
Frequency classification
50Hz
Short circuit classification
63 A (max. admissible backup fuse)
Leakage current type
A
Nominal residual closing and disconnection capacity
500 A
Permissible overload of the previous fuse - max.
25 A gG/gL
Nominal short-term withstand current (Icw)
10 kA
Current surge capacity
0.25 kA
Test circuit range
196 V AC - 264 V AC
Degree of contamination
2
Electrical useful life
4000 operations
Technical Data - Mechanical
Frame
45mm
Width in number of modular spaces
4
Built-in width (number of units)
70 mm (4 SU)
Built-in depth
70.5 millimeters
Assembly method
DIN rail
Quick fixing with 2 latch positions for DIN rail IEC/EN 60715
Degree of protection
IP20, IP40 with suitable housing
IP20
Terminals (upper and lower)
Open mouth/lifting terminals
Terminal capacity (solid wire)
1.5 mm² - 35 mm²
Cross section of pluggable conductor (solid core) - min.
1.5 mm²
Connectable conductor cross section (solid core) - max.
35mm²
Terminal capacity (stranded cable)
16 mm² (2x)
Connectable conductor section (multi-wiring) - min.
1.5 mm²
Connectable conductor section (multi-wiring) - max.
16mm²
Terminal protection
Safe for fingers and hands, DGUV VS3, EN 50274
Busbar material thickness
0.8 millimeters - 2 millimeters
Useful life, mechanics
20000 operations
Permissible storage and transportation temperature - min.
-35ºC
Permissible storage and transportation temperature - max.
60 ºC
Climate test
25-55 °C / 90-95% relative humidity according to IEC 60068-2