Acpclima air conditioning, lighting and everything for the home
Send to:
Send to:
BLACK10: 10% discount on all products in the store except OUTLET. Minimum amount €80

S204-C20 Circuit Breaker - 4P - C - 20 A 2Cds254001R0204

Brand: ABB

Reference: 2CDS254001R0204

Offer: €84.81
PVP: €227.29
€84.81
  • Quantity
  • Available stock
    Taxes included
    Free shipping

Description

S204-C20 Circuit Breaker - 4P - C - 20 A 2Cds254001R0204

Details

More information

The reference 2CDS254001R0204 specifically, is a magneto-thermal switch.

Its characteristics are:

Assigned breaking capacity Icu according to EN 60947-2 at 230 V: 20kA, Solid connectable conductor section: 0.75 - 35 mm², Connectable conductor section: 0.75 - 25 mm², Ambient temperature during operation: -25 - 55 °C, Additional equipment possible, Number of poles (total): 4, Rated breaking capacity Icu according to EN 60947-2 at 400 V: 20kA, Rated breaking capacity Icn according to EN 60898 to 230 V: 6kA, Rated voltage peak resistance (Uimp): 4kV, Number of protected poles: 4, Rated breaking capacity Icn according to EN 60898 at 400 V: 6kA, Frequency: 50Hz.

Technical

Rules:

IEC/EN 60898-1

IEC/EN 60947-2

UL 1077

Stumble feature:

C

Nominal operating voltage:

acc. to IEC 60898-1 400 V AC

acc. to IEC 60898-1 400 V

acc. to IEC 60947-2 440 V AC

Operating voltage:

Maximum (Incl. Tolerance) 440 V AC

Minimum 12 V AC

Minimum 12 V DC

Nominal insulation voltage (Ui):

acc. to IEC/EN 60664-1 440 V

Nominal voltage supported by impulses (Uimp):

4 kV

at 2000 m 5 kV

at Sea Level 6.2 kV

Dielectric test voltage:

50/60 Hz, 1 min: 2 kV

Input voltage type:

AC/DC

Nominal current (In):

20 A

Nominal short circuit capacity:

(AC) 6 kA

(DC) 6 kA

(400 V AC) 6 kA

(400 V) 6 kA

Nominal short-circuit breaking capacity (Icu):

(230 V AC) 20 kA

(400 V AC) 10 kA

(440 V AC) 10 kA

(230 V) 20 kA

(400 V) 10 kA

Rated conditional short circuit current (Inc):

(230 V) 20 kA

(400 V) 20 kA

Nominal short-circuit breaking capacity in service (Ics):

(230 V AC) 15 kA

(400 V AC) 7.5 kA

(440 V AC) 7.5 kA

Frequency (f):

50 Hz

Nominal frequency (f):

50 / 60 Hz

Power loss:

10 W

at Rated Operating Conditions per Pole 2.5 W

Power supply connection:

Arbitrary

Contact position indication:

Red ON / Green OFF

Power limitation class:

3

Electrical resistance:

20000 AC cycle

Mechanical resistance:

20000 cycle

Number of protected posts:

4

Number of poles:

4

Surge category:

III

Tightening torque:

2.8 N·m

Mounting type:

DIN-Rail

Screw terminal type:

Failsafe Bi-directional Cylinder-lift Terminal

Actuator marking:

I/O

Actuator material:

Insulation Group II, Black, Sealable

Housing material:

Insulation Group II, RAL 7035

Mounting on contactors:

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Mounting position:

any

Recommended screwdriver:

Pozidriv 2

Available accessories:

Yes

Connection capacity:

Busbar 10 / 10 mm²

Flexible with Ferrule 0.75 ... 25 mm²

Flexible 0.75 ... 25 mm²

Rigid 0.75 ... 35 mm²

Rigid 0.75 ... 35 mm²

Stranded 0.75 ... 35 mm²

Installation size:

acc. to DIN 43880 1

Cable stripping length:

12.5mm

Terminal type:

Screw Terminals

Material Compliance

RoHS information:

2CDK403001D0607

RoHS status:

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

RoHS date:

0335

REACH declaration:

9AKK108468A9644

REACH information:

True - contains substances > 0.1 mass percentage

REACH date:

20231212

Conflict Minerals Reporting Template (CMRT):

9AKK108468A3363

SCIP:

e6800e55-46b1-49a3-881b-0f66d0e903ad Germany (DE)

Environment

Ambient temperature:

Operation -25 ... +55 °C

Storage -40 ... +70 °C

Reference ambient air temperature:

30 °C

Degree of protection:

IP20

IP40

Enclosure with Cover IP40

Degree of contamination:

3

Environmental conditions:

28 cycles

with 55 °C / 90-96 %

and 25 °C / 95-100 %

Vibration resistance according to IEC 60068-2-6:

20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz

Shock resistance according to IEC 60068-2-27:

25g 2 shocks 13 ms

Technical UL/CSA

UL/CSA maximum operating voltage:

110V DC

480Y/277V AC

Interrupting capacity according to UL1077:

(277 V AC) 6 kA

(480Y / 277 V AC) 6 kA

(240 V) 10 kA

UL/CSA connection capacity:

Busbar 18-8 AWG

Conductor 18-4 AWG

UL/CSA tightening torque:

18 in·lb

Dimensions

Width in number of modular spaces:

4

Product width:

70mm

Height of the product:

88mm

Product length:

69mm

Product weight:

0.5 kg

Pole net weight:

0.125 kg

Built-in depth (t2):

69mm

Dimensions diagram:

2CDC022007F0010

Comments

There are no opinions yet Be the first to review!

Questions

No questions yet Do you have any doubt?

Best price

Have you seen it cheaper?
×

Receive our news

See details + -
By checking this option we will send you the best offers and exclusive promotions and discounts to your email address. You can unsubscribe at any time.
Set your cookies preferences
We use cookies and similar technologies to offer you a personalized, safe, reliable experience and to be able to measure page performance to continue improving our services. For more information or to edit your cookie preferences at any time, check the Cookies policy page
Go out