Brand: Eaton
Reference: 248442
Z-Lhasa/230 Emission Coil Shunt Trigger, for advanced industrial and commercial applications. Eaton brand.
Z-Lhasa/230 Emission Coil Shunt Trigger, for advanced industrial and commercial applications. Eaton brand.
Product name
Eaton distribution parts
Part number.
Z-LHASA/230
Product length/depth
80 millimeters
Height of the product
75 millimeters
Product width
39.1 millimeters
Product Weight
0.158 kilograms
Compliance
RoHS Compliant
Certifications
IEC 61373
EN45545-2
Commercial name of the product
None
type of product
Distribution parts
Product subtype
None
Public consumption
Yes
Description of the product family
ES-PMCC-PDC-Eaton Distribution parts
Globally marketable
Yes
Product specification details
Type of accessory/spare part
bypass release
Additional equipment required
Bypass release (for power circuit breaker)
Ambient operating temperature - max.
40ºC
Ambient operating temperature - min.
-5ºC
Request
Switchgear for advanced industrial and commercial applications
Mounting width
1.5
Device assembly
Miniature circuit breaker (MCB)
EL number
1609566
Functions
Bypass release (for power circuit breaker)
Number of contacts (investor contacts)
0
Number of contacts (normally closed contacts)
1
Number of contacts (normally open contacts)
1
Number of poles in the main contact unit - max.
1
Number of switches (fault signal)
0
Nominal operating voltage (Ue) - max.
230 volts
Nominal current of the switch
2A
Suitable for main contact unit current - max.
2A
Type
Accessory
Accessory for miniature circuit breaker
Used with
Bypass releases
Voltage type
C.A.
TECHNICAL DATA ETIM 9.0
Distribution board/surface mounting devices (EG000062) / Auxiliary device for distribution board devices (EC001286)
Electrical engineering, automation, process control engineering / Electrical installation, device / Circuit breaker switch component / Auxiliary contact unit for distribution board (ecl@ss13-27-14-35-02 [AKE327018 ])
Device assembly
Miniature circuit breaker (MCB)
Function
Bypass release (for power circuit breaker)
Width in number of modular spaces
1.5
Number of contacts as normally open contact
1
Number of contacts as normally closed contact
1
Number of contacts as reversing contact
0
Number of fault signal switches
0
Nominal current of the switch
2A
Nominal voltage
230 volts
Voltage type
C.A.
With automatic test for ground leakage function.
No
Suitable for max. number of poles main contact unit (total)
1
Suitable for max. current main contact unit
2A